The Perl Toolchain Summit needs more sponsors. If your company depends on Perl, please support this very important event.

NAME

Tinkerforge::BrickletIndustrialQuadRelay - 4 galvanically isolated solid state relays

CONSTANTS

DEVICE_IDENTIFIER

This constant is used to identify a Industrial Quad Relay Bricklet.

The get_identity() subroutine and the CALLBACK_ENUMERATE callback of the IP Connection have a device_identifier parameter to specify the Brick's or Bricklet's type.

DEVICE_DISPLAY_NAME

This constant represents the display name of a Industrial Quad Relay Bricklet.

CALLBACK_MONOFLOP_DONE

This constant is used with the register_callback() subroutine to specify the CALLBACK_MONOFLOP_DONE callback.

FUNCTION_SET_VALUE

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_VALUE

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_SET_MONOFLOP

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_MONOFLOP

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_SET_GROUP

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_GROUP

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_AVAILABLE_FOR_GROUP

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_SET_SELECTED_VALUES

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_IDENTITY

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTIONS

new()

Creates an object with the unique device ID *uid* and adds it to the IP Connection *ipcon*.

set_value()

Sets the output value with a bitmask (16bit). A 1 in the bitmask means relay closed and a 0 means relay open.

For example: The value 3 or 0b0011 will close the relay of pins 0-1 and open the other pins.

If no groups are used (see :func:`Set Group`), the pins correspond to the markings on the Industrial Quad Relay Bricklet.

If groups are used, the pins correspond to the element in the group. Element 1 in the group will get pins 0-3, element 2 pins 4-7, element 3 pins 8-11 and element 4 pins 12-15.

All running monoflop timers will be aborted if this function is called.

get_value()

Returns the bitmask as set by :func:`Set Value`.

set_monoflop()

Configures a monoflop of the pins specified by the first parameter bitmask.

The second parameter is a bitmask with the desired value of the specified pins. A 1 in the bitmask means relay closed and a 0 means relay open.

The third parameter indicates the time (in ms) that the pins should hold the value.

If this function is called with the parameters (9, 1, 1500) or (0b1001, 0b0001, 1500): Pin 0 will close and pin 3 will open. In 1.5s pin 0 will open and pin 3 will close again.

A monoflop can be used as a fail-safe mechanism. For example: Lets assume you have a RS485 bus and a Quad Relay Bricklet connected to one of the slave stacks. You can now call this function every second, with a time parameter of two seconds and pin 0 closed. Pin 0 will be closed all the time. If now the RS485 connection is lost, then pin 0 will be opened in at most two seconds.

get_monoflop()

Returns (for the given pin) the current value and the time as set by :func:`Set Monoflop` as well as the remaining time until the value flips.

If the timer is not running currently, the remaining time will be returned as 0.

set_group()

Sets a group of Quad Relay Bricklets that should work together. You can find Bricklets that can be grouped together with :func:`Get Available For Group`.

The group consists of 4 elements. Element 1 in the group will get pins 0-3, element 2 pins 4-7, element 3 pins 8-11 and element 4 pins 12-15.

Each element can either be one of the ports ('a' to 'd') or 'n' if it should not be used.

For example: If you have two Quad Relay Bricklets connected to port A and port B respectively, you could call with ``['a', 'b', 'n', 'n']``.

Now the pins on the Quad Relay on port A are assigned to 0-3 and the pins on the Quad Relay on port B are assigned to 4-7. It is now possible to call :func:`Set Value` and control two Bricklets at the same time.

get_group()

Returns the group as set by :func:`Set Group`

get_available_for_group()

Returns a bitmask of ports that are available for grouping. For example the value 5 or 0b0101 means: Port A and port C are connected to Bricklets that can be grouped together.

set_selected_values()

Sets the output value with a bitmask, according to the selection mask. The bitmask is 16 bit long, *true* refers to a closed relay and *false* refers to an open relay.

For example: The values (3, 1) or (0b0011, 0b0001) will close the relay of pin 0, open the relay of pin 1 and leave the others untouched.

If no groups are used (see :func:`Set Group`), the pins correspond to the markings on the Industrial Quad Relay Bricklet.

If groups are used, the pins correspond to the element in the group. Element 1 in the group will get pins 0-3, element 2 pins 4-7, element 3 pins 8-11 and element 4 pins 12-15.

Running monoflop timers for the selected relays will be aborted if this function is called.

get_identity()

Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.

The position can be 'a', 'b', 'c' or 'd'.

The device identifier numbers can be found :ref:`here <device_identifier>`. |device_identifier_constant|