NAME

Tinkerforge::BrickletAmbientLightV3 - Measures ambient light up to 64000lux

CONSTANTS

DEVICE_IDENTIFIER

This constant is used to identify a Ambient Light Bricklet 3.0.

The get_identity() subroutine and the CALLBACK_ENUMERATE callback of the IP Connection have a device_identifier parameter to specify the Brick's or Bricklet's type.

DEVICE_DISPLAY_NAME

This constant represents the display name of a Ambient Light Bricklet 3.0.

CALLBACK_ILLUMINANCE

This constant is used with the register_callback() subroutine to specify the CALLBACK_ILLUMINANCE callback.

FUNCTION_GET_ILLUMINANCE

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_SET_ILLUMINANCE_CALLBACK_CONFIGURATION

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_ILLUMINANCE_CALLBACK_CONFIGURATION

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_SET_CONFIGURATION

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_CONFIGURATION

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_SPITFP_ERROR_COUNT

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_SET_BOOTLOADER_MODE

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_BOOTLOADER_MODE

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_SET_WRITE_FIRMWARE_POINTER

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_WRITE_FIRMWARE

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_SET_STATUS_LED_CONFIG

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_STATUS_LED_CONFIG

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_CHIP_TEMPERATURE

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_RESET

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_WRITE_UID

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_READ_UID

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_IDENTITY

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTIONS

new()

Creates an object with the unique device ID *uid* and adds it to the IP Connection *ipcon*.

get_illuminance()

Returns the illuminance of the ambient light sensor. The measurement range goes up to about 100000lux, but above 64000lux the precision starts to drop. The illuminance is given in lux/100, i.e. a value of 450000 means that an illuminance of 4500lux is measured.

An illuminance of 0lux indicates an error condition where the sensor cannot perform a reasonable measurement. This can happen with very dim or very bright light conditions. In bright light conditions this might indicate that the sensor is saturated and the configuration should be modified (:func:`Set Configuration`) to better match the conditions.

If you want to get the value periodically, it is recommended to use the :cb:`Illuminance` callback. You can set the callback configuration with :func:`Set Illuminance Callback Configuration`.

set_illuminance_callback_configuration()

The period is the period with which the :cb:`Illuminance` callback is triggered periodically. A value of 0 turns the callback off.

If the `value has to change`-parameter is set to true, the callback is only triggered after the value has changed. If the value didn't change within the period, the callback is triggered immediately on change.

If it is set to false, the callback is continuously triggered with the period, independent of the value.

It is furthermore possible to constrain the callback with thresholds.

The `option`-parameter together with min/max sets a threshold for the :cb:`Illuminance` callback.

The following options are possible:

.. csv-table:: :header: "Option", "Description" :widths: 10, 100

 "'x'",    "Threshold is turned off"
 "'o'",    "Threshold is triggered when the value is *outside* the min and max values"
 "'i'",    "Threshold is triggered when the value is *inside* or equal to the min and max values"
 "'<'",    "Threshold is triggered when the value is smaller than the min value (max is ignored)"
 "'>'",    "Threshold is triggered when the value is greater than the min value (max is ignored)"

If the option is set to 'x' (threshold turned off) the callback is triggered with the fixed period.

get_illuminance_callback_configuration()

Returns the callback configuration as set by :func:`Set Illuminance Callback Configuration`.

set_configuration()

Sets the configuration. It is possible to configure an illuminance range between 0-600lux and 0-64000lux and an integration time between 50ms and 400ms.

The unlimited illuminance range allows to measure up to about 100000lux, but above 64000lux the precision starts to drop.

A smaller illuminance range increases the resolution of the data. A longer integration time will result in less noise on the data.

If the actual measure illuminance is out-of-range then the current illuminance range maximum +0.01lux is reported by :func:`Get Illuminance` and the :cb:`Illuminance` callback. For example, 800001 for the 0-8000lux range.

With a long integration time the sensor might be saturated before the measured value reaches the maximum of the selected illuminance range. In this case 0lux is reported by :func:`Get Illuminance` and the :cb:`Illuminance` callback.

If the measurement is out-of-range or the sensor is saturated then you should configure the next higher illuminance range. If the highest range is already in use, then start to reduce the integration time.

get_configuration()

Returns the configuration as set by :func:`Set Configuration`.

get_spitfp_error_count()

Returns the error count for the communication between Brick and Bricklet.

The errors are divided into

* ACK checksum errors, * message checksum errors, * framing errors and * overflow errors.

The errors counts are for errors that occur on the Bricklet side. All Bricks have a similar function that returns the errors on the Brick side.

set_bootloader_mode()

Sets the bootloader mode and returns the status after the requested mode change was instigated.

You can change from bootloader mode to firmware mode and vice versa. A change from bootloader mode to firmware mode will only take place if the entry function, device identifier and CRC are present and correct.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

get_bootloader_mode()

Returns the current bootloader mode, see :func:`Set Bootloader Mode`.

set_write_firmware_pointer()

Sets the firmware pointer for :func:`Write Firmware`. The pointer has to be increased by chunks of size 64. The data is written to flash every 4 chunks (which equals to one page of size 256).

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

write_firmware()

Writes 64 Bytes of firmware at the position as written by :func:`Set Write Firmware Pointer` before. The firmware is written to flash every 4 chunks.

You can only write firmware in bootloader mode.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

set_status_led_config()

Sets the status LED configuration. By default the LED shows communication traffic between Brick and Bricklet, it flickers once for every 10 received data packets.

You can also turn the LED permanently on/off or show a heartbeat.

If the Bricklet is in bootloader mode, the LED is will show heartbeat by default.

get_status_led_config()

Returns the configuration as set by :func:`Set Status LED Config`

get_chip_temperature()

Returns the temperature as measured inside the microcontroller. The value returned is not the ambient temperature!

The temperature is only proportional to the real temperature and it has bad accuracy. Practically it is only useful as an indicator for temperature changes.

reset()

Calling this function will reset the Bricklet. All configurations will be lost.

After a reset you have to create new device objects, calling functions on the existing ones will result in undefined behavior!

write_uid()

Writes a new UID into flash. If you want to set a new UID you have to decode the Base58 encoded UID string into an integer first.

We recommend that you use Brick Viewer to change the UID.

read_uid()

Returns the current UID as an integer. Encode as Base58 to get the usual string version.

get_identity()

Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.

The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an :ref:`Isolator Bricklet <isolator_bricklet>` is always at position 'z'.

The device identifier numbers can be found :ref:`here <device_identifier>`. |device_identifier_constant|